After updating HPE Integrated Lights-Out 5 (iLO 5) to firmware v3.0 (or later) the cpqDaPhyDrvCurrentTemperature OID no longer returns a proper value:Before the update:iLO 5 firmware v2.91:cpqDaPhyDrvCurrentTemperature .1.3.6.1.4.1.232.3.2.5.1.1.70[root@DL385G10K5U33 ~]# snmpwalk -v 2c 10.65.175.18 -c public .1.3.6.1.4.1.232.3.2.5.1.1.70SNMPv2-SMI::enterprises.232.3.2.5.1.1.70.0.1 = INTEGER: 33SNMPv2-SMI::enterprises.232.3.2.5.1.1.70.0.2 = INTEGER: 36SNMPv2-SMI::enterprises.232.3.2.5.1.1.70.0.3 = INTEGER: 34After the update:iLO 5 firmware v3.06:[root@DL385G10K5U33 ~]# snmpwalk -v 2c 10.65.175.18 -c public .1.3.6.1.4.1.232.3.2.5.1.1.70SNMPv2-SMI::enterprises.232.3.2.5.1.1.70.0.1 = INTEGER: -1SNMPv2-SMI::enterprises.232.3.2.5.1.1.70.0.2 = INTEGER: -1SNMPv2-SMI::enterprises.232.3.2.5.1.1.70.0.3 = INTEGER: -1SNMPv2-SMI::enterprises.232.3.2.5.1.1.70.2.1 = INTEGER: -1SNMPv2-SMI::enterprises.232.3.2.5.1.1.70.2.2 = INTEGER: -1This occurs because iLO 5 uses the RDE path for the source of this data starting with iLO 5 firmware 3.0. This is part of an effort towards adopting DMTF standards.
Any HPE system with iLO 5 updated to iLO firmware v3.0 (or later).
There is an internal mapping for SNMP properties to DMTF properties. If it exists in the SNMP and does not have a mapping on RDE from DMTF, then it will function. The OID cpqDaPhyDrvCurrentTemperature has not been updated because RDE does not support it. BMIC support was previously confined to SR controllers; consequently, in iLO5 this OID can be implemented and updated only for SR controllers. A future mapping will be added into the DMTF Redfish WG to add those properties so they can be properly enumerated for the MR controllers. . When these mappings are available, this advisory will be updated.Document VersionRelease DateDetails2March 4, 2026Updated Resolution.1November 5, 2024Original Document Release.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.