The following alert may be displayed in the in the HPE Integrated Lights-Out 6 (iLO 6) or iLO 7 -> Information -> Security Log UI after a server with an iLO 6 or iLO 7 boots:SPDM device at location PCI-E Slot X could not bHPE Integrated Lights-Out 6 (iLO 6)e authenticated (reason SPDM GET_VERSION Unsupported)OrSPDM device at location OCP 3.0 Slot X could not be authenticated (reason SPDM GET_VERSION Unsupported)These iLO security events can be safely ignored as the functionality of the device is not affected.
Any HPE system with iLO 6 or iLO 7 except the HPE ProLiant RL3xx Gen11 systems that do not support Security Protocol and Data Model (SPDM).This has been observed on the Intel E810‑XXVDA2 Ethernet 10/25Gb 2‑port SFP28 OCP3 adapter however, this may occur with any device that does not support the SPDM specification v1.0, v1.0.1, v1.1 or v1.2.
Ignore the iLO security events as they do not affect the functionality of the device.This security event is logged by iLO for any device that does not support the SPDM specification v1.0, v1.0.1, v1.1 or v1.2 that iLO 6 supports. This is working as designed.Refer to theSecure Protocol and Data Modelsection of the iLO 6 andSecure Protocol and Data Modelsection of the iLO 7 User Guide for additional information.Document VersionRelease DateDetails3April 28, 2026Added iLO 7 as affected.2December 9, 2024Added alerts can be viewed in in the iLO 6 -> Information -> Security Log UI.1October 22, 2024Original Document Release.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.