Document VersionRelease DateDetails2September 6, 2023Updated Resolution with an OS independent firmware package and added a recommendation to reboot the system after a firmware update.1August 21, 2023Original Document Release.A limited number of HPE 800-watt Flex-slot Titanium Low Halogen power supplies (PSU), SKU:865438-B21 / PN:865436-101 / SPN:866793-001, built with firmware version 2.0, may potentially encounter an intermittent issue during some load conditions that cause the power supply to report an erroneous PSU protection fault and a generate General power supply fault message in the Integrated Management Log (IML).The server does not shut down if one PSU remains active in redundant power supply configurations. However, the general power supply fault/failure could cause a system reset, depending on the configuration and load on the system at the time of the fault.When this occurs, the following message will be written in the IML and the green LED on the PSU will not be illuminated:IML Entry:Caution,171,2219,0x000B,Power,0x0028,Hardware, Power,11/03/2022 07:57:57,90: System Power Supply: General Failure (Power Supply X) ACTION: Replace the power supply.
Any HPE Gen10, Gen10 Plus or Gen11 servers using 800W Power Supply Unit with HW Revision 20F to 23F (Rev. mark is located on the PSU sticker) and firmware v2.0 (found in iLO). These hardware revisions were shipped between July 2022 and August 2023.Note: 01F to 19F revisions with the FW 1.0 are not affected by this issue.PN:865436-101GPN:865435-001SPN:866793-001OPTION KIT PN: 865438-B21
This is an erroneous error message condition generated by the 2.0 firmware. To resolve the issue, upgrade the power supply firmware from 2.0 to 2.01.It is not necessary to update the firmware if the current version is other than 2.0, the update will stop if the detected firmware version is 1.0 or if the power supply is already running firmware version 2.01. The Hardware Revision information can be obtained from the power supply sticker as mentioned in the Scope section, without having to power on the server.Before updating the firmware, keep the power supply units in healthy status so that the system can communicate properly. If the power supply unit is offline, try unplugging and reconnecting the power cord first.Windows Smart Component 2023.07.17 (2 Aug 2023):Software Details - Online Power Supply Flash Component for Windows - HPE Flexible Slot Power SuppliesLinux Smart Component 2023.07.17 (2 Aug 2023):Software Details - Online Power Supply Flash Component for Linux - HPE Flexible Slot Power SuppliesOS independent Firmware Package 2023.07.17(25 Aug 2023):ROM Flash Firmware Package - HPE Flexible Slot Power Supplies for HPE ProLiant ServersNote: To ensure that you have selected the latest version of the firmware/driver, click the Revision History tab to check if a new version of the firmware/driver is available. For more important information, review the Release Notes tab.In order to correctly activate the fix, a cold reboot is recommended after a firmware package update. Follow any of the methods below to cold reboot:Manually shutdown from the operating system and then power on.ORPress the 'Cold Boot' virtual button in ILO, the server shuts down and will restart after approximately 8 seconds.ORUse the ILOREST command to remove the power immediately, followed by a restart:ilorest reboot coldboot --url $ILO_ADDRESS -u $ILO_USER -p $ILO_PASSWORDORUse the Redfish command for cold boot:curl -i --insecure -u ${ILO_USER}:${ILO_PASSWORD} -X POST -H "Content-Type: application/json" -d '{"ResetType":"ColdBoot"}' https://$ILO_ADDRESS/redfish/v1/Systems/1/Actions/Oem/Hpe/HpeComputerSystemExt.SystemReset/As a workaround, try reseating the power supply unit and ensure the power distribution unit (PDU) and rack chassis are properly grounded.Hardware revisions are being reworked to use firmware version 2.01, revision 24F and newer will use firmware version 2.01 as a default.Power supply units, with a hardware revision prior to 24F, that are flashed at the factory with firmware version 2.01 will have a blue ink mark as shown in the following image:RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:HPE Email Preference Center.NAVIGATION TIP:For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to theNavigation Tips document.SEARCH TIP:For hints on locating similar documents on HPE.com, refer to theSearch Tips document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.