IMPORTANT: The firmware update is considered a critical fix and is required to prevent the issue detailed below. HPE strongly recommends immediate application of this critical fix. Neglecting to perform the required action could leave the Storage array in an unstable condition, which could potentially result in temporary data unavailability or data loss. By disregarding this notification and not performing the recommended resolution, the customer accepts the risk of incurring future related errors.A firmware issue was discovered on drive model ST12000NM008G which could lead to failure of MSA 2060 Array drives and subsequent removal from the disk-group degrading fault tolerance. This issue causes an IOEDC error to fail on the Hard Disk Drive (HDD).Identifying the IssueThe disk drive error LED will be illuminated when this issue occurs.An alert will be displayed in the Storage Management Utility Dashboard, indicating a critical disk error.To verify the failure, the vendor, model number, and revision of the drive, perform the following:Log into the Storage Management Utility.Click onMaintenance>Hardware.Click on the affected HDD to display the details.
HPE HDD model ST1200NM008G with drive firmware versions prior to EF04 are affected by this issue.
To prevent this issue, update the MSA 2060 Array drive firmware on model ST12000NM008G to version EF04 or later as soon as possible to avoid any issues with multiple drive failures that could cause data to go offline.If the issue has already occurred, replace the disk and update the drive firmware on the drives.The drive failure issue is resolved in the EF04 firmware available for the ST12000NM008G drive.TheEF04 firmware, which was released on August 22, 2022, is available on the HPE Support Center website.NOTE: Drives running EF04 firmware are no longer susceptible to the above-stated issue.See theHPE MSA Storage Firmwarepage on the HPE website for details regarding MSA controllers, disk enclosures, drives and other related links.IMPORTANT:HPE strongly recommends immediate application of this resolution.Ensure that all data is backed up prior to any updates.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:HPE Email Preference Center
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.