On any of the HPE Gen10 Plus, Gen11 or Gen12 servers mentioned in the Scope section below running SUSE Linux Enterprise Server 15 SP4 or SP6, and using the Intel Virtual RAID on CPU (VROC), the correspondingmdadmgrow command will not function properly for Online Capacity Expansion (OCE) on OS RAID volume, as shown in the first picture below.When the mdadm command is executed, the RAID reshaping process (shown in the second picture below) is not initiated as expected.The expected result when the RAID reshape is initiated successfully is as follows:The migration result can be verified by checking the /proc/mdstat file.This issue does not occur on data RAID volume.
Any of the following HPE Gen10 Plus, Gen11 or Gen12 servers running SUSE Linux Enterprise Server 15 SP4 or SP6 and using the Intel Virtual RAID on CPU (VROC):HPE Alletra Storage Server 4110HPE Alletra Storage Server 4120HPE Alletra Storage Server 4140HPE Edgeline e920 Server BladeHPE Edgeline e920d Server BladeHPE Edgeline e920t Server BladeHPE ProLiant DL110 Gen10 Plus Telco serverHPE ProLiant DL110 Gen11HPE ProLiant DL20 Gen10 Plus serverHPE ProLiant DL20 Gen11HPE ProLiant DL320 Gen11HPE ProLiant DL360 Gen10 Plus serverHPE ProLiant DL360 Gen11HPE ProLiant DL380 Gen10 Plus serverHPE ProLiant DL380 Gen11HPE ProLiant DL380a Gen11HPE ProLiant DL560 Gen11HPE ProLiant MicroServer Gen11HPE ProLiant ML110 Gen11HPE ProLiant ML30 Gen10 Plus serverHPE ProLiant ML30 Gen11HPE ProLiant ML350 Gen11HPE ProLiant Compute DL380a Gen12HPE ProLiant Compute DL320 Gen12HPE ProLiant Compute DL360 Gen12HPE ProLiant Compute DL380 Gen12HPE ProLiant Compute ML350 Gen12HPE ProLiant Compute DL340 Gen12HPE ProLiant Compute DL580 Gen12
For SUSE Linux Enterprise Server 15 SP4:Update the mdadm package to mdadm-4.1-150300.24.30.1, refer toRecommended update for mdadm SUSE-RU-2023:3542-1for additional information.For SUSE Linux Enterprise Server 15 SP6:A new mdadm package will be released in future for this issue, and this document will be updated when more information is available.Before new mdadm package release, use the command below:systemctl start mdadm-grow-continue@<md container>.serviceWhere <md container> is md container (eg. md127).If there is no matrix raid, typing "systemctl start mdadm-grow", and hitting tab to autocomplete the command should also work.Document VersionRelease DateDetails5July 28, 2025Updated affected servers and Resolution.4October 23, 2023Updated Resolution with permanent fix.3March 20, 2023Additional Gen11 Servers have been added.2February 2, 2023Added HPE Gen11 Servers and Alletra Storage Servers affected by this issue.1December 6, 2022Original Document Release.
Operating Systems Affected:SUSE Linux Enterprise Server 15
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.