Document VersionRelease DateDetails3November 18, 2022A sentence was added at the end of the first paragraph in the Description section.2October 18, 2022The Resolution was updated to reflect the version of HPE ProLiant Gen10 and Gen10 Plus Smart Array Controller Driver that resolves this issue.1September 7, 2022Original Document Release.Any server configured with HPE Smart Array SR Gen10 Controllers running firmware version 5.00 fails to shut down when connected to the tape storage on HPE Red Hat Enterprise Linux (RHEL) 7 and 8, and the process does not complete while using theshutdowncommand. An error message will be displayed on the console, and the shutdown failure occurs. The issue has also been observed when running the commandmt -f /dev/nst0 statusto check the tape status.See the following shutdown error.Computer Output Error E208[ 840.337986] INFO: task sg_map:13794 blocked for more than 120 seconds.[ 840.344567] "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message.[ 840.352448] sg_map D ffff8c04b789acc0 0 13794 13792 0x00000080[ 840.359578] Call Trace:[ 840.362053] [<ffffffffa9385d89>] schedule+0x29/0x70[ 840.367056] [<ffffffffa9383891>] schedule_timeout+0x221/0x2d0[ 840.372931] [<ffffffffa90e2850>] ? scsi_dispatch_cmd+0xb0/0x240[ 840.378978] [<ffffffffa90eba98>] ? scsi_request_fn+0x48/0x660[ 840.384849] [<ffffffffa938613d>] wait_for_completion+0xfd/0x140[ 840.390899] [<ffffffffa8cdb990>] ? wake_up_state+0x20/0x20[ 840.396521] [<ffffffffc0848a87>] st_do_scsi.constprop.23+0x297/0x420 [st][ 840.403442] [<ffffffffc084ab4c>] check_tape+0x5ac/0x950 [st][ 840.409225] [<ffffffffc084b206>] st_open+0x316/0x3d0 [st][ 840.414744] [<ffffffffa8e527b5>] chrdev_open+0xb5/0x1b0[ 840.420089] [<ffffffffa8e4a872>] do_dentry_open+0x1e2/0x2d0[ 840.425785] [<ffffffffa8f07932>] ? security_inode_permission+0x22/0x30[ 840.432440] [<ffffffffa8e52700>] ? cdev_put+0x30/0x30[ 840.437611] [<ffffffffa8e4a9fa>] vfs_open+0x5a/0xb0[ 840.442605] [<ffffffffa8e590c3>] ? may_open+0xa3/0x120[ 840.447864] [<ffffffffa8e5cfa6>] do_last+0x1f6/0x1340[ 840.453035] [<ffffffffa8e5e1bd>] path_openat+0xcd/0x5a0[ 840.458379] [<ffffffffa8e6040d>] do_filp_open+0x4d/0xb0[ 840.463724] [<ffffffffa8e6e437>] ? __alloc_fd+0x47/0x170[ 840.469158] [<ffffffffa8e4bfe4>] do_sys_open+0x124/0x220[ 840.474588] [<ffffffffa8e4c0fe>] SyS_open+0x1e/0x20[ 840.479583] [<ffffffffa9392ed2>] system_call_fastpath+0x25/0x2a
The following HPE Smart Array SR Gen10 Controllers with firmware version 5.00 are affected by this issue:HPE Smart Array E208e-p SR Gen10 (8 External Lanes/No Cache) 12G SAS PCIe Plug-in Controller (804398-B21)HPE Smart Array P408e-m SR Gen10 (8 External Lanes/2GB Cache) 12G SAS Mezzanine Controller (804381-B21)HPE Smart Array P408e-p SR Gen10 (8 External Lanes/4GB Cache) 12G SAS PCIe Plug-in Controller (804405-B21)HPE Smart Array P416ie-m SR Gen10 (8 Int 8 Ext Lanes/2GB Cache) 12G SAS Mezzanine Controller (804428-B21)
Unplug the system power cable for a minimum of 30 seconds, and then plug it back in.This issue is resolved in HPE ProLiant Gen10 and Gen10 Plus Smart Array Controller Driver 2.1.18-045 (or later), available as follows:Red Hat Enterprise Linux 7 (64-bit)Red Hat Enterprise Linux 8 (64-bit)As a workaround, downgrade HPE ProLiant Gen10 and the Gen10 Plus Smart Array Controller Firmware Version 4.11 at the following URLs.VMware ESXiLinux (x64)Windows (x64)RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:HPE Email Preference CenterNAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HPE.com, refer to theSearch Tips document.
Operating Systems Affected:Red Hat Enterprise Linux 7 Server, Red Hat Enterprise Linux 7 Workstation (x86-64), Red Hat Enterprise Linux 8 Server
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.