The manufacturer of the SAS Expander card (876907-001 SPS-PCA, SA PCIe SAS Expander) has changed the hardware that now requires 5.10 or later component firmware installed on the card.This issue is documented in Customer Advisory a00121106:HPE StoreOnce Storage - Incorrect Recommendation Displayed to Downgrade HBA Firmware After SAS Expander Card Replacement When Using StoreOnce Systems With Software 4.3.0 or EarlierAnother potential issue may affect customers using the new type of replacement SAS Expander card while running legacy HPE StoreOnce software. When a software upgrade of the HPE StoreOnce system is completed, an automatic component firmware checking process is started. This process will upgrade or downgrade the component firmware to the supported level. Any customer running a legacy version of HPE StoreOnce software, and having the SAS Expander card replaced with a new type that requires at least 5.10 firmware, may lose access to the data stored on the HPE StoreOnce system when upgrading to HPE StoreOnce software version 4.3.0 or earlier, due to above described automatic firmware downgrade process.
This issue affects any HPE StoreOnce Gen10-based systems built with 12G SAS Expander Cards running HPE StoreOnce software version 4.3.0 or earlier.
This issue is resolved in the HPE StoreOnce software version 4.3.2 release.WorkaroundBefore upgrading to HPE StoreOnce software version 4.3.0, check if the SAS expander card has a firmware version earlier than 5.10 and there are no event log messages with the following description:The HBA firmware needs to be downgraded.Only start the software upgrade process if the SAS expander card has a firmware version earlier than 5.10. Contact HPE Support for further assistance.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:HPE Email Preference Center
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.