Document VersionRelease DateDetails2July 7, 2022Revised the Resolution section.1March 11, 2022Original Document release.An issue occurs with some SN3700M and SN3700cM switch interfaces 1/1-1/8 and 1/25-1/32 and SN4600cM switch interfaces 1/1-1/32 running-config viewing when a "Miscellaneous other settings" section is shown appended near the end of the startup running-config. This issue can be observed immediately after first power-on execution of the start-up wizard or by bypassing the startup wizard and going to the CLI. Theshow runCLI command can confirm the presence of "Miscellaneous other settings," which indicates there is a manageability issue. An example of the symptom on a SN3700cM is shown below:## Miscellaneous other settings##internal set modify - /iss/config/vcm/interface/129/fec value uint8 4...internal set modify - /iss/config/vlan/interface/129/switchport/mode value string access...internal set modify - /iss/config/vlan/interface/189/switchport/pvid value uint16 1internal set modify - /iss/config/vlan/interface/189/switchport/scope value string ignore#### Persistent prefix mode setting##cli default prefix-modes enableThis issue has occurred on some SN4600cM, SN3700M, and SN3700cM switches during the manufacturing process when installing ONYX-3.9.2110 on both flash partitions. When a switch is affected by this issue, SN3700M and SN3700cM interfaces 1/1-1/8 and 1/25-1/32, and SN4600cM interface 1/1-1/32 configuration cannot be seen in the running configuration file. The CLI interface configuration and show commands are effective, and the switch functions correctly. However, not being able to see the interface running configuration makes switch management difficult. An example of the running configuration not showing interface configurations for interfaces 1/1-1/8 and 1/25-1/32 is shown below. Notice that no information is shown for interfaces 1/1-1/8 and 1/25-1/32 even though they have been configured and are properly functioning:switch-741e92 [standalone: master] (config) # show run#### Running database "initial"## Generated at 2022/03/06 16:46:46 +0000## Hostname: switch-741e92## Product release: 3.9.2110###### Running-config temporary prefix mode setting##no cli default prefix-modes enable#### Interface Ethernet configuration##interface ethernet 1/9-1/24 flowcontrol receive on forceinterface ethernet 1/9-1/24 flowcontrol send on force#### VLAN configuration##vlan 2interface ethernet 1/9-1/24 switchport access vlan 2#### STP configuration##interface ethernet 1/9-1/24 spanning-tree port type edge#### L3 configuration##vrf definition mgmt#### QoS switch configuration##interface ethernet 1/9-1/24 qos trust portinterface ethernet 1/9-1/24 qos default switch-priority 4interface ethernet 1/9-1/24 qos rewrite pcpExamples of a few CLI commands which may be used to indirectly view the interface configuration:switch-741e92 [standalone: master] (config) # show interfaces ethernet statusswitch-741e92 [standalone:master] (config) # show vlanswitch-741e92 [standalone: master] (config) # show interfaces ethernet 1/1switch-741e92 [standalone: master] (config) # show interfaces ethernet link-diagnostics
The following HPE StoreFabric M-Series ONYX switches are affected by this advisory:HPE SN3700cM 100GbE 32QSFP28 Power to Connector (P2C) Airflow Switch (R3B14A)HPE SN3700M 200GbE 32QSFP28 Power to Connector (P2C) Airflow Switch (R5Z74A)HPE SN4600cM 100GbE 64QSFP28 Power to Connector (P2C) Airflow Switch (R6R24A)
A disruptive process to "reset factory" after upgrading to ONYX-3.9.3220 or to ONYX-3.10.2202 images, and saving the running configuration, returns the switch to a factory reset state without "Miscellaneous other settings" observed in the running configuration.(config) # reset factory keep-basicOr(config) # reset factoryNOTE: (config) # reset factory keep-all-configpreserves the "Miscellaneous other settings" and should not be utilized.The M-series manufacturing process, as of May 2022, installs ONYX-3.9.3220 to resolve this issue, which was introduced with ONYX-3.9.2110.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:HPE Email Preference Center.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.