Loading...
Loading...
Document VersionRelease DateDetails2February 2, 2023Updated the Resolution to reflect the version of firmware that resolves this issue.1February 8, 2022Original document release.HPE Smart Array Gen10 controllers connected to a HPE D8000 Disk Enclosures using firmware version 0118 may report an error message, "Storage Enclosure Firmware Upgrade Problem Detected" during server POST or in the server IML logs.Check the D8000 Disk Enclosures front panel LED. If the D8000 disk enclosure is not reporting any fault LED status after applying v0118, then the Smart Array error message, "Storage Enclosure Firmware Upgrade Problem Detected", is only a reporting issue. There is no hardware fault with the enclosure.If the D8000 disk enclosure is reporting a fault LED (amber) status after applying v0118, there may be a firmware mismatch on one or more subcomponents.If the configuration is a mixed mode (HBA) configuration with two nodes, the v0118 firmware update process must be executed from each node.Generate an ADU report for each node.Review - Enclosure SEP (HPE D8000), is reporting firmware version, 0118Review – Enclosure Expander, check each instance is reporting firmware version, 0118If any component is reporting an older revision, execute the D8000 v0118 from that node.
HPE D8000 Disk Enclosures are affected by this issue.
This issue is resolved in HPE D8000 Disk Enclosures version 0130.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:HPE Email Preference Center.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.