Document VersionRelease DateDetails304/27/2021Content heavily revised in the Title, Description, Scope, and Resolution sections.209/13/2016Revised the Description section.109/01/2016Original Document Release.For HPE 3PAR File Controller and HPE StoreEasy Storage Systems running Windows Storage Server or Windows Server IoT, the Initial Configuration Tasks application logging level may be set too high. The logging level may be set to "All," which will result in the creation of multi-GB log files, causing significant consumption of OS drive space. Log files will grow as long as the Initial Configuration Tasks application is running.
The following products are affected by this issue:StoreEasy products affected:HPE Storage File ControllersHPE 3PAR StoreServ File ControllerHPE StoreEasy 1000 StorageHPE StoreEasy 3000 Gateway StorageHPE StoreEasy 3000 Gateway Storage BladeWindows server versions affected:Windows Storage Server 2012 R2Windows Storage Server 2016Windows Storage Server 2019 IOT for Storage
Configuration Modification InstructionsFollow the steps below to modify the logging level for the Initial Configuration Tasks application:Close the Initial Configuration Tasks application if it is open (the Server Manager window will open).Go to thec:\windows\system32\oemoobefolder.Edit themsoobe_oem.exe.configfile using Notepad.Find the following lines:<source name="Microsoft.Windows.OemOobe.Msoobe.Tracing" switchValue="All"><source name="Microsoft.Windows.OemOobe.Common.Tracing" switchValue="All">Change the valueAlltoErrorin each line. You may also change the value ofswitchValueto any of the other levels; however, higher logging levels result in larger log files. The file contains a definition of each level.Save the file.You can remove the existing log filemsoobe.txt.If you are not actively using the Initial Configuration Tasks application, HPE recommends that you doNOTlaunch the application. However, if you need to re-launch the application, enter the commandc:\windows\system32\oemoobe\oemoobe.exeat a command prompt, or pressWindows+R.NOTE: For clustered solutions, you must complete these steps on each node of the cluster.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:Proactive Updates Subscription Form.
Operating Systems Affected:Microsoft Windows Server 2012 R2, Microsoft Windows Server 2016, Microsoft Windows Server 2019
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.