Document VersionRelease DateDetails2February 3, 2023The Resolution was updated to reflect the version of firmware that resolves this issue.1April 20, 2021Original Document Release.A ProLiant Gen9 server Integrated Management Log (IML) may not record a degraded D3000 component when the following components are running these specific firmware versions:D3000 firmware version 5.04Gen9 Smart Array Controller firmware version 7.00iLO4 Firmware version 2.70Host applications such as iLO or SSA will report the degraded state of the D3000 component.The HPE D3000 Enclosure has the ability to report failure or degraded condition on the IOM 7-Segment display on the enclosure. The 7-segment codes can be located in theD3000 Maintenance and Service Guide.
HPE D3600 and D3700 Enclosures are affected by this issue.
This issue is resolved in HPE Smart Array Gen9 v7.20 firmware.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:Proactive Updates Subscription Form.