On any Logical Interconnect with two HPE Virtual Connect SE 100Gb F32 Modules for Synergy configured in an Active-Standby uplink configuration, all uplink ports may transition to a blocking state during a disruptive firmware update.This issue may occur when updating from any version prior to 2.2.0 to version 2.2.0. Once version 2.2.0 has been installed, this issue will not occur on subsequent updates.When this issue occurs, all Synergy compute modules associated with the affected uplink ports will temporarily lose all Network connectivity. This occurs when the Virtual Connect module that has the active LAG in the uplink set is activated as part of the firmware update, and until it initializes while running the new firmware version.This issue will only occur if the configured Ethernet uplink sets are not configured with MLAG. For example, an uplink set with 4 separate single-port LAGs will experience this issue; however, an Ethernet uplink set that has MLAG configured will not encounter this issue.Note:This issue does not affect Fibre Channel uplink sets.Additional information regarding MLAG and other configuration modes can be found in the following technical paper:HPE Virtual Connect traffic flow with HPE SynergyAdditional information regarding disruptive and non-disruptive firmware updates can be found at the following link:HPE Virtual Connect SE 100Gb F32 Module for Synergy Release Notes
In the scenario described above, any HPE Virtual Connect SE 100Gb F32 Module for Synergy.
This issue has been resolved in Virtual Connect firmware version 2.2.0 (or later). Once version 2.2.0 has been installed, this issue will not occur on subsequent updates. This version can be found in theHPE Synergy Software Releasespage.This issue will auto-recover in approximately 15 minutes.To avoid this issue, perform the following workaround:Reconfigure the Upstream switches (typically Top of Rack switches) for MLAG traffic flow as described starting on page 16 of the above mentioned technical paper.Note:Refer to the documentation of the switch vendor, for steps on how-to configure LACP trunk ports.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP:For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads to HPE Platforms and options, refer to theNavigation Tips document.SEARCH TIP:For hints on locating similar documents on HPE.com, refer to theSearch Tips document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.