With HPE MSA Storage, the Virtual Snapshot and Replication Snapshots snap suffix is limited. An issue occurs when replication uses snapshot retention policy and snapshot suffix crosses number 9999. For the suffix 10000, only the first four (4) digits are considered, and Snapshot is created as "Snapshot_1000". For suffix 10001, only the first four (4) digits are considered, and again it tries to create Snapshot "Snapshot_1000" and fails since duplicate names already exist. Similar failures are seen for 10002 through 10009. The subsequent successful run is for suffix 10010 with snapshot name "Snapshot_1001".The following events are seen in the event log:B111593 2020-03-30 17:34:26 108 INFORMATIONAL A volume was deleted.(vdisk: B, volume: MHF-RZA_9999, SN: 00c0ff4389cc000031d9815e01000000)B1115942020-03-30 17:34:26 604 WARNING A replication snapshot failed to be created. Aduplicate name was specified. (volume name: MHF-RZA, SN:00c0ff4389cc0000a6456e5d01000000)
This issue can occur on any HPE MSA G4 (1040/2040/2042) or G5 (1050/2050/2052) array configured with Virtual Replication sets.Standard snapshots are not affected by this issue.
Delete and re-create the Replication set.Schedule the Replication less often, extending the time before reaching the limits. Once the issue has occurred, the Replication set will need to be re-created.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.