Document VersionRelease DateDetails502/24/2020Revised firmware versions in the Resolution section.410/05/2020Added switches SN2100M, SN2010M and related content to the Description, Scope and Resolution section.309/09/2020Content was revised in the Description, Scope, and Resolution sections.205/11/2020SSD Drive Types were revised in the Resolution section.105/06/2020Original Document Release.An SSD controller firmware issue has been identified with some SN2100M, SN2010M, SN2700M, SN2410M, and SN2410bM switches. The failure caused by this operational issue is random and SSD-usage dependent and is often recoverable by ONYX operation retries. However, the issue may cause a switch to become unresponsive or an ONYX upgrade to fail. Performing successive ONYX image upgrades is more likely to experience this issue and cause the update to fail. After a failure, a switch reload may recover operational status. This SSD controller firmware issue can be repaired by an image update using the standalone SSD update image (image-X86_64-ssd_fw_update_util_011.img). This update process is disruptive. The standalone image can be uploaded to the switch using the same procedure as a regular ONYX image upgrade using either CLI or the switch WEB U/I.
The following HPE M-Series switches are affected by this issue:HPE M-Series SN2100M Ethernet Switch Models:HPE SN2100M 100GbE16QSFP28 Half-Width Switch [Q2F23A]HPE SN2100M 100GbE8QSFP28 Half-Width Switch [Q2F24A]HPE SN2100M 100GbE16QSFP28 Power to Connector Airflow Half TAA-compliant [R0P75A]HPE SN2100M 100GbE16QSFP28 Connector to Power Airflow Half TAA-compliant [R0P76A]HPE M-Series SN2010M Ethernet Switch Models:HPE SN2010M 25GbE18SFP28 4QSFP28 Switch [Q9E63A]HPE SN2010M 25GbE18SFP28 4QSFP28 Power to Connector Airflow TAA-compliant [R0P77A]HPE SN2010M 25GbE18SFP28 4QSFP28 Connector to Power Airflow TAA-compliant [R0P78A]HPE M-Series SN2700M Ethernet Switch Models:HPE SN2700M 100GbE32QSFP28 Switch [Q2F21A]HPE SN2700M 100GbE32QSFP28 Power to Connector Airflow TAA-compliant [R0P71A]HPE SN2700M 100GbE32QSFP28 Connector to Power Airflow TAA-compliant [R0P72A]HPE SN2700M 100GbE16QSFP28 Switch [Q6M26A]HPE M-Series SN2410M Ethernet Switch Models:HPE SN2410M 25GbE48SFP28 8QSFP28 Switch [Q2F22A]HPE SN2410M 25GbE48SFP28 8QSFP28 Power to Connector Airflow TAA-compliant [R0P73A]HPE SN2410M 25GbE48SFP28 8QSFP28 Connector to Power Airflow TAA-compliant [R0P74A]HPE SN2410M 25GbE24SFP28 4QSFP28 Switch [Q6M27A]HPE SN2410bM 10GbE48SFP+ 8QSFP28 Switch [Q6M28A]HPE SN2410bM 10GbE24SFP+ 4QSFP28 Switch [Q6M29A]M-series SN2100M, SN2010M, SN2700M, SN2410M, and SN2410bM switch models are affected by an SSD controller firmware issue.Failure Symptom: SSD becomes read only:This causes switch firmware corruption during updates.The symptom is often recoverable with switch software retries or switch reload.Not all switches with this specific SSD are affected.Currently shipping SSDs are not exposed to this SSD controller firmware issue.
Identify an ONYX M-series switch affected by down revision SSD firmware following the instructions in the following document:M-series_SSD_Flash_Firmware_Update_User_Guide-revision3.pdfA shortcut method to check a switch with Innodisk SSD controller utilizes thefae show smartCLI command (not available prior to ONYX 3.7.1200). The Innodisk SSD controller firmware revision in some SN2010M and SN2100M switches is included in the SMART data shown by this command output. To obtain the SN2700M, SN2410M, and SN2410bM Virtium StorFly SSD firmware revision, a sysdmp must be generated, downloaded, expanded, and thesysinfo.txt filesearched for the SMART data section. For both SSD types, the sysdmp sysinfo method will provide the necessary revision check. However, if you are not sure of the SSD firmware revision or have an issue obtaining the revision, the image tool can be loaded and run. The image tool determines the SSD type and revision and update requirement. Once determined, perform the SSD update if required, which restarts the previously active ONYX image.The SSD drive type is affected by similar issues which need updating:SN2100M and SN2010MM.2 (S42) 3ME3 Firmware Version S15A19M.2 (S42) 3ME3 Firmware Version S16425MM.2 (S42) 3ME3 Firmware Version S19903MM.2 (S42) 3IE3 Firmware Version S16425iM.2 (S42) 3IE3 Firmware Version S19903MiSN2700M, SN2410M, and SN2410bMStorFly VSF302XC016G-MLX Firmware Version 0115-000Examples of two SSD drive types that do not have any known issues and do not need to be upgraded with this tool:SSDPN: VSF302XC016G-MLX1 (SSD Firmware Version: 0202)SSDPN: DHM24-16GD09BC1DC-92 (SSD Firmware Version: S17411i)TheSSD firmware update toolis recommended to be run once per switch as soon as possible or prior to the next ONYX update.Refer to theONYX User Guide, located on each switch, for instructions on installing an ONYX image file utilizing the WEB U/I or CLI on M-series switches.ThisM-series switch User Manualis viewable using the switch's Web U/I documentation tab or can be located at theHPE Support Centerunder theM-series switch modeldocumentation tab.Also, refer to the document which guides you through the SSD update process:M-series_SSD_Flash_Firmware_Update_User_Guide-revision3.pdf.This is available in the HPE support portal for each switch model.For ONIE switch models, an SSD controller firmware standalone software tool update process is available; contact the NOS provider for assistance.TheRead_Me_firstfile provides a brief description of theSSD firmware update image tool and User guide.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.