Document VersionRelease DateDetails27 February 2020Added the second sentence in the Resolution section117 January 2020Original Document ReleaseAn issue has been identified with HPE XP7 storage systems running firmware version 80-06-66-00 (M177) and earlier where attempts to perform management operations using either the graphic user interface (GUI) or command line interface (CLI) on the service processor (SVP) gradually take longer to complete or may timeout.Symptoms when using Device Manager (DevMgr), Replication Manager (RepMgr), and Tiered Storage Manager (TSMgr)DevMgr, RepMgr, or TSMgrOperations using DevMgr, RepMgr, or TSMgr to manage storage systems gradually slow down, and ultimately fail because of a timeout.Symptoms when using Automation Director (AD)When executing a service linked to Configuration Manager (CM), task execution times gradually become longer. Ultimately, tasks fail because of timeouts.Symptoms when using CMA CM API operation might take 20 minutes or longer.ImpactFor DevMgr, RepMgr, and TSMgr:Frequency of issue:HighSeverity of issue:MediumFor AD and CM:Frequency of issue:LowSeverity of issue:High
This issue affects HPE XP7 storage systems as well as the following HPE Storage Management Software products:Device Manager 5.6.0-00 or laterTiered Storage Manager 5.6.0-00 or laterReplication Manager 5.6.0-00 or laterAutomation Director 8.5.2-00 or laterConfiguration Manager 8.5.1-00 or later
This issue is resolved in HPE XP7 firmware version 80-06-70-00/00 (M183), released in October 2019. Contact HPE Support for assistance upgrading to the latest version of XP7 firmware.WorkaroundThe issue can be corrected temporarily by rebooting the SVP. Call HPE Support for assistance with rebooting the SVP.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.