If a 16Gb SFP is plugged into a 32Gb FC HBA which is installed in an HPE Primera running 4.0.1, it will be non-functional, but it will not generate an alert or an event. Similarly, a 32Gb SFP installed in a 16Gb HBA will be non-functional. The 'showport' commands will validate that there is an issue:'showport' command output will indicate a state of loss_sync'showport –sfp' will reportTXDisable=Yes‘shownode –pci’ command will show what model of HBA is present (which will also show 16Gb or 32Gb)From the GUI, go toSystem > Controllers > Node # > View Detailson the slot number of the HBA to show the speed of the HBA
This issue affects HPE Primera 630, 650, and 670 systems running OS version 4.0.1.
Ensure that the SFP speed matches the speed of the HBA:878405-001 SPS-16Gb SFP+ SW E Temp PT 1pk XCVR878404-001 SPS-32Gb SFP28 SW E Temp PT 1pk XCVRP00765-001 SPS-ADPTR PRIMERA 600, FC, 32Gb, 4-PORTP00764-001 SPS-ADPTR PRIMERA 600, FC, 16Gb, 4-PORTIf an SFP with the wrong speed was installed as a replacement, then that SFP will need to be replaced with one of the correct speed.RECEIVE PROACTIVE UPDATES: Receive support alerts (such asCustomer Advisories), as well as updates on drivers, software, firmware, andcustomer replaceable components, proactively in your e-mail through HPESubscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from