On HPE ProLiant Gen8 servers or an HPE ProLiant DL580 Gen9 server configured with HPE Smart Array Px3x 4GB Cache Module controllers running firmware version 4.54 (or earlier), the following POST error messages may be reported during reboot or during boot after an ungraceful shutdown:1793-Slot 2 Drive Array - Data in Write-Back Cache has been Lost1797-Slot 2 Drive Array - Write-Back Cache Backup Previously Failed. Caching is disabled.The following POST error message may be seen if the controller has Smart Array SR SmartCache configured:1831-Slot 2 Drive Array - Data in Write-Back SmartCache has been lost. Action: Restore data from backupThis issue occurs because the battery is not fully charged on the HPE Smart Array Px3x controllers with 4GB cache module.Note: The errors above may also be seen after replacing the batteries.
Any HPE ProLiant Gen8 servers or HPE ProLiant DL580 Gen9 server configured with any of the following HPE Smart Array products:HPE Smart Array P430/4GB FBWC 12Gb 1-port Int SAS Controller (Part Number 698530-B21)HPE Smart Array P431/4GB FBWC 12Gb 2-ports Ext SAS Controller (Part Number 698532-B21)HPE Smart Array P830/4GB FBWC 12Gb 2-ports Int PCIe x8 SAS Controller (Part Number 698533-B21)HPE Smart Array P830i/4GB Controller SPI board (For DL580 Gen8/Gen9)
To prevent this issue from occurring, upgrade the Smart Array Px3x controller to firmware version 5.02 (or later). Obtain Smart Array firmware release 5.02 by clicking one of the links below depending on the operating system installed:Linux:https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_330456640bee4a069f7317cab0Windows:https://www.hpe.com/global/swpublishing/MTX-7f9840894d3d417c9e7db6d3d6VMware:https://www.hpe.com/global/swpublishing/MTX-7037593885ac4b2395563657b9Note: To check if a new firmware version is available, click the Revision History tab on the download page.If the issue is encountered and aPOST error 1793 or 1831is reported, perform the upgrade to Smart Array firmware version 5.02 and ensure no battery failure exists. Then, proceed to restore data from a backup.If the HPE Smart Array SR Px3x controller with 4GB cache module reports battery failure after firmware version 5.02 (or later) has been installed, replace the failed battery with the following spare:Battery pack - 4.3V NiMH (Nickel Metal Hydride Battery) Part Number 731125-001RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for HPE systems and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HPE.com, refer to theSearch Tips Document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.