Document VersionRelease DateDetails210/06/2020Updated the Resolution section.102/22/2019Original Document Release.If an HPE D3000 Disk Enclosure is configured with SATA HDD or SATA SSD drives, the SATA drives may not be discovered after a power cycle of a server. This behavior may result in the logical drive missing disk members or logical drive going offline.
Firmware version 4.12 or earlier on the following HPE D3000 enclosures are affected by this issue:HPE D3600 EnclosureHPE D3610 EnclosureHPE D3700 EnclosureHPE D3710 Enclosure
This issue is resolved in v5.04 firmware for D3600, D3700, D3610, D3710, and D6020 enclosures, which is located on HPESC forLinux,WindowsandESX.WorkaroundIf the SATA drives do not start, the server can be restarted one or more times until the drives start and the smart array acknowledges the member are online again, and the logical drive can be enabled.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.