Loading...
Loading...
For HPE MSA 1040, 2040, and 2042 SAN Storage arrays that are configured with both email and syslog alerting, the alert level will be set at the syslog level (not the email level). If only email is configured and syslog remains at its default setting, the alert level will be set according to the email alerting configuration.
All arrays with GL200 firmware and later for the following product families are affected by this issue.HPE MSA 1040 SAN StorageHPE MSA 2040 SAN StorageHPE MSA 2042 SAN Storage
If both email and the syslog are to be used for alerting, set the syslog alert level needed to the required level for both email and the syslog. Only one alert level can be used when both syslog and email are configured. The alert level for email will be ignored when the syslog is configured.If you wish to no longer use syslog and use only email for alerting, set the alert level on syslog to "None." The email alert level will now be used.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.