The Windows Server 2016 Operating System intermittently fails to boot on an HPE ProLiant server when all of the following conditions are met:The Operating System is installed on a Boot LUN provisioned from an HPE MSA 1050/2050 Storage Array connected directly to the Emulex 8Gb AdapterThe Operating System is running the inbox Emulex fibre channel adapter driverThe 81E/82E Adapter Topology has been set to "AUTO Point to Point first" and Speed Link to "8 GB/s"The HPE MSA 2050 Storage Array port that is connected to the Adapter has the Connection Mode as "point to point" and the Speed as "auto"The following error message is seen on the console during boot:Stop Code: INACCESSIBLE BOOT DEVICEThough the boot LUN is discovered during OS installation, it is not accessible during the boot process. This is due to an intermittent link negotiation failure in the LPe12002 firmware when directly connected to the MSA.
This issue will affect any system which has an Emulex-based 8Gb Fibre Channel adapter installed that is directly connected to an HPE MSA 1050/HPE MSA 2050 Storage System. It also requires that the system is running Windows 2016 and running the Emulex adapter drivers which came with the operating system (11.0.x.x).Emulex-based 8Gb Fibre Channel adapter installed:HPE 81E 8Gb 1-port PCIe Fibre Channel Host Bus AdapterHPE 81E 8Gb 1-port PCIe Fibre Channel Host Bus Adapter/S-BuyHPE 82E 8Gb 2-port PCIe Fibre Channel Host Bus AdapterHPE 82E 8Gb 2-port PCIe Fibre Channel Host Bus Adapter/S-BuyHPE MSA 1050/2050 Storage Array:HPE MSA 1050 8Gb Fibre Channel Dual Controller LFF StorageHPE MSA 1050 8Gb Fibre Channel Dual Controller SFF StorageHPE MSA 1050 SAN StorageHPE MSA 2050 SAN Dual Controller LFF StorageHPE MSA 2050 SAN Dual Controller SFF Storage
This issue has been addressed in the HPE driver 11.4.225.9, available at:https://support.hpe.com/hpsc/swd/public/detail?sp4ts.oid=1009474100&swItemId=MTX_c6191811bf0a4ef6b1a386c7f7&swEnvOid=4184It is recommended to upgrade to this driver (or later) as soon as possible.As a workaround, set the "Connection Mode" to "auto" for the port of HPE MSA 2050 Storage Array that is connected to the LPe12002 adapter.NOTE: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HPE.com, refer to theSearch Tips Document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.