HPE 3PAR StoreServ Storage small form factor (SFF) SSD models that start with "DOP" and are listed in Table 1 are being discontinued. Spare parts for the discontinued DOPx drives are transitioning to alternate drive models also listed in Table 1. The supply of discontinued drives is diminishing rapidly, and some models will be very limited, or out, in early 2018.To prepare for this transition, ensure that any HPE 3PAR StoreServ array with these discontinued drive models meets or exceeds the Alternate Replacement OS Requirement specified in Table 1. Once the discontinued drives are no longer available, HPE will be unable to replace the failed drive until the array is upgraded as specified in the Resolution section of this advisory.Please note that not all drive models starting with "DOP" are listed in Table 1. For those drive models not listed, this advisory does not apply. Also, this advisory does not apply to large form factor (LFF) versions of any DOPx drive models listed in Table 1.NOTE: Drive models can be determined using the HPE 3PAR StoreServ Management Console (SSMC) or the 3PAR CLIshowpd -icommand.To ensure that the 3PAR StoreServ array is able to accept the alternate replacement spare part, check that either:The array already has the alternate replacement model listed in Table 1 installed in the array.Or:The array meets or exceeds the Alternate Replacement OS Requirement specified in Table 1.If either of the above is true, no action is required. Replace any failed DOPx drives with the corresponding alternate replacement spare part number.Otherwise, carefully follow the procedure outlined in the Resolution section of this advisory.Table 1 - Discontinued SFF SSD Spare Parts and Alternate Replacement Spare PartsNOTE: Some discontinued drive models have two alternate replacement models.System ModelCapacity in GBDiscontinued SSD Model and (Form Factor)Discontinued Spare PartAlternate Replacement SSD ModelAlternate Replacement Spare PartAlternate Replacement OS Requirement*7000480DOPE0480S5xnNMRI(SFF)778179-001AREA0480S5xnNTRI879387-0013.2.2-MU4+P74 or (P94+P95) or P101,3.2.2-MU3+(P75 or P89 or P97),3.2.2-MU2+(P77 or P81 or P83),3.2.1-MU5+(P72 or P76 or P82),3.2.1-MU3+(P73 or P77 or P79),3.2.1-MU2+P83Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.7000920DOPA0920S5xnNMRI(SFF)761926-001AREA0920S5xnNTRI879388-0013.2.2-MU4+P74 or (P94+P95) or P101,3.2.2-MU3+(P75 or P89 or P97),3.2.2-MU2+(P77 or P81 or P83),3.2.1-MU5+(P72 or P76 or P82),3.2.1-MU3+(P73 or P77 or P79),3.2.1-MU2+P83Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.70001920DOPE1920S5xnNMRI(SFF)778180-001DDYE1920S5xnNMRI873099-001(First choice alternate)3.2.2-MU4+P58 or P74 or (P94+P95) or P101,3.2.2-MU3+(P89 or P97),3.2.2-MU2+(P81 or P83),3.2.1-MU5+(P58 or P70 or P82),3.2.1-MU3+(P77 or P79),3.2.1-MU2+P83Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.70001920DOPE1920S5xnNMRI(SFF)778180-001AREA1920S5xnNTRI879390-001(Second choice alternate)3.2.2-MU4+P74 or (P94+P95) or P101,3.2.2-MU3+(P75 or P89 or P97),3.2.2-MU2+(P77 or P81 or P83),3.2.1-MU5+(P72 or P76 or P82),3.2.1-MU3+(P73 or P77 or P79),3.2.1-MU2+P83Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.70003840DOPM3840S5xnNMRI(SFF)806214-001DDYE3840S5xnNMRI873094-001(First choice alternate)3.2.2-MU4+(P58+P73) or P74 or (P94+P95) or P101,3.2.2-MU3+(P89 or P97),3.2.2-MU2+(P81 or P83),3.2.1-MU5+(P58 or P70 or P82),3.2.1-MU3+(P77 or P79),3.2.1-MU2+P83Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.70003840DOPM3840S5xnNMRI(SFF)806214-001AREA3840S5xnNTRI879392-001(Second choice alternate)3.2.2-MU4+P74 or (P94+P95) or P101,3.2.2-MU3+(P75 or P89 or P97),3.2.2-MU2+(P77 or P81 or P83),3.2.1-MU5+(P72 or P76 or P82),3.2.1-MU3+(P73 or P77 or P79),3.2.1-MU2+P83Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.8000480DOPE0480S5xnNMRI(SFF)810770-001AREA0480S5xnNTRIP00888-0013.2.2-MU4+(P91 or P95 or P101),3.2.2-MU3+(P93 or P97),3.2.2-MU2+(P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.80001920DOPE1920S5xnNMRI(SFF)810771-001DDYE1920S5xnNMRI873103-001(First choice alternate)3.2.2-MU4+P58 or P74 or (P94+P95) or P101,3.2.2-MU3+(P89 or P97),3.2.2-MU2+(P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.80001920DOPE1920S5xnNMRI(SFF)810771-001AREA1920S5xnNTRI879389-001(Second choice alternate)3.2.2-MU4+P74 or (P94+P95) or P101,3.2.2-MU3+(P75 or P89 or P97),3.2.2-MU2+(P77 or P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.80003840DOPM3840S5xnNMRI(SFF)810773-001DDYE3840S5xnNMRI873101-001(First choice alternate)3.2.2-MU4+(P58+P73) or P74 or (P94+P95) or P101,3.2.2-MU3+(P89 or P97),3.2.2-MU2+(P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.80003840DOPM3840S5xnNMRI(SFF)810773-001AREA3840S5xnNTRI879391-001(Second choice alternate)3.2.2-MU4+P74 or (P94+P95) or P101,3.2.2-MU3+(P75 or P89 or P97),3.2.2-MU2+(P77 or P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.20000480DOPE0480S5xnNMRI(SFF)809585-001AREA0480S5xnNTRIP00889-0013.2.2-MU4+(P91 or P95 or P101),3.2.2-MU3+(P93 or P97),3.2.2-MU2+(P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.200001920DOPE1920S5xnNMRI(SFF)809590-001DDYE1920S5xnNMRI873102-001(First choice alternate)3.2.2-MU4+P58 or P74 or (P94+P95) or P101,3.2.2-MU3+(P89 or P97),3.2.2-MU2+(P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.200001920DOPE1920S5xnNMRI(SFF)809590-001AREA1920S5xnNTRI879400-001(Second choice alternate)3.2.2-MU4+P74 or (P94+P95) or P101,3.2.2-MU3+(P75 or P89 or P97),3.2.2-MU2+(P77 or P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.200003840DOPM3840S5xnNMRI(SFF)809589-001DDYE3840S5xnNMRI872801-001(First choice alternate)3.2.2-MU4+(P58+P73) or P74 or (P94+P95) or P101,3.2.2-MU3+(P89 or P97),3.2.2-MU2+(P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.200003840DOPM3840S5xnNMRI(SFF)809589-001AREA3840S5xnNTRI879403-001(Second choice alternate)3.2.2-MU4+P74 or (P94+P95) or P101,3.2.2-MU3+(P75 or P89 or P97),3.2.2-MU2+(P77 or P81 or P83)Note: For 3.2.2-MU6 and later (including 3.3.1), no patch is required.*When multiple patches are listed for a 3PAR OS version:"or" means that the highest-numbered patch supersedes the lower-numbered patch (or patches)."+" means that the combination of patches supersedes the lower-numbered patch (or patches). The combination of patches must be installed.
This advisory applies to all HPE 3PAR StoreServ Storage 7000, 8000 and 20000 arrays with one or more of the discontinued SFF drive models installed that are listed in Table 1.
To ensure the 3PAR StoreServ Storage array accepts the alternate replacement spare part, carefully follow the steps outlined in Table 2 below, the Action Plan Decision Matrix. This will require:The DOPx SSD models installed in the array. This can be obtained from the output of the 3PAR CLI commandshowpd -i.The 3PAR OS version and patches installed on the array. This can be obtained from the output of the 3PAR CLI commandshowversion.Table 2 - Action Plan Decision MatrixCriteriaRequired ActionArray meets or exceedsthe Alternate Replacement OS Requirement specified in Table 1 above for DOPx SSD models installed in the array.No action is required.Array requires only a drive-enablement patch(versus an MU upgrade or more) listed in Table 3 below.Apply the appropriate drive-enablement patch listed in Table 3.If needed, contact the Global Deployment Center (GDC) athttps://ent302.sharepoint.hpe.com/teams/GSDERRepository/GSDERCSCOLA/SitePages/Home.aspxfor upgrade planning and assistance to enable the array to accept the alternate spare drive model.Array requires more than a patch(such as an MU or OS upgrade) to apply a drive-enablement patch listed in Table 3 below.NOTE: With a failed drive, an MU or full OS upgrade of the 3PAR StoreServ array can only proceed in an offline manner.Contact the Global Deployment Center (GDC) athttps://ent302.sharepoint.hpe.com/teams/GSDERRepository/GSDERCSCOLA/SitePages/Home.aspxfor upgrade planning and assistance to enable the array to accept the alternate spare drive model.Table 3 - Drive-Enablement Patches for DOPx Alternate Drive ModelsCurrent 3PAR OS VersionDrive-Enablement Patch3.2.2-MU43.2.2-MU4 P1013.2.2-MU33.2.2-MU3 P973.2.2-MU23.2.2-MU2 P833.2.1-MU53.2.1-MU5 P823.2.1-MU33.2.1-MU3 P793.2.1-MU23.2.1-MU2 P83HPE 3PAR StoreServ 7000, 8000 and 9000 systems support the option of customers performing OS updates, along with Service Processor (SP) updates, with the exception of SP 4.x to 5.x updates. We urge customers to refer to the relevant update and release note documentation and to carefully review the dependencies of various host environments provided in the information library. If you are not confident in updating or applying patches, contact Global Deployment Services (GDS) as documented below.Link to Information Library:https://www.hpe.com/info/storage/docs/HPE 3PAR StoreServ 10000 and 20000 systems DO NOT support the customer performing OS updates. Contact the GDS as documented below.Contacting the Global Deployment Services (GDS):Please refer to the following article to request a 3PAR StoreServ OS patch or update:https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00061484en_usRECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.