An issue has been identified with HPE StoreOnce systems when upgrading to software version 3.16.3 or later from any version earlier than version 3.16.3 where the HPE StoreOnce management interfaces may become inaccessible after the upgrade.This issue will occur if the configuration for network usage is set to "data" instead of "both" on HPE StoreOnce software versions 3.16.3 or later. Setting usage to "both" allows for both management and data usage, whereas setting to "data" blocks management traffic.Prior to HPE StoreOnce software version 3.16.3, the netusage tag was not used, so CLI network configuration commandsnet set addressandnet create subnetwould set the netusage tag's default value to "data" instead of "both" in HPE StoreOnce versions 3.16.2 and earlier. As of HPE StoreOnce software version 3.16.3, this value is now used to enable the separation of management and data networks.As part of the software upgrade process, the existing network configurations are checked to ensure there is at least one subnet that has a netusage value of either "mgmt." or "both". In some cases, there may be a subnet that has access to the management interfaces, but it may not be the subnet normally used to access the HPE StoreOnce system.For information to prevent the issue before upgrading the HPE StoreOnce system, or for recovering management access if the issue has occurred, see the Workaround section.
This issue affects the following HPE StoreOnce single-node and VSA systems running HPE StoreOnce software versions earlier than 3.16.3:BB910A HPE StoreOnce 2900 BackupBB903A HPE StoreOnce 4900 BackupBB877A HPE StoreOnce 2700 8TB BackupBB878A HPE StoreOnce 4500 24TB BackupBB879A HPE StoreOnce 4700 24TB BackupTC458A/TC458AAE HP StoreOnce VSA 10 TB 3 Year SoftwareD4T77A/D4T77AAE HP StoreOnce VSA 4 TB 3 Year SoftwareD4U47A/D4U47AAE HP StoreOnce VSA 50TB 3-year LTU/E-LTUD4U49A/D4U49AAE HP StoreOnce VSA 4TB 5-year LTU/E-LTUD4U62A/D4U62AAE HP StoreOnce VSA 10TB 5-year LTU/E-LTUD4U48A/D4U48AAE HP StoreOnce VSA 50TB 5-year LTU/E- LTU
See the Workaround section to avoid or resolve this issue as part of upgrading from software versions earlier than 3.16.3. HPE StoreOnce systems running software version 3.16.3 or later with working management network access are no longer exposed to this issue.WorkaroundIf the system has not been updated, create and activate a new network configuration before upgrading.To create a new network configuration using the HPE StoreOnce GUI:SelectDevice Configuration > Network Configuration > Custom,then clickNew.NOTE: Do NOT use the "copy" option to copy any existing configuration.OrTo create a new network configuration using the HPE StoreOnce CLI:Use the commandnet set wizardto be guided through creating a new network configuration.NOTE: Do NOT use other CLI commands to create the new network configuration.The HPE StoreOnce system can now be upgraded to software version 3.16.3 or later.If the system has been updated, try to access the HPE StoreOnce management interface using all configured IP addresses. If successful, follow these steps to modify the current network configuration by using the HPE StoreOnce GUI:SelectDevice Configuration > Network Configuration > Custom, and then clickNew.Give the new configuration a name (for example, "new_config").Ensure theCopy Existingcheckbox is selected, and select thecurrentconfiguration from the drop-down list. Here is an example of the Create popup:Select the portset containing the subnet used to access the management interfaces, then select the subnet from the grid and clickEdit.Change the Type to eitherManagementorBoth, then clickOKto accept the changes. Here is an example of the edit subnet popup:ClickValidateto validate the configuration, followed byActivateto activate the new configuration. Here is an example of the Activate popup:If you cannot access the HPE StoreOnce GUI, follow these steps to modify the current network configuration using the HPE StoreOnce CLI:Access the CLI using either:an alternative configured IP addresses on a different subnet,orthrough the local consoleEnter the following commands to make a copy of the current configuration, and then modify that copy to change the netusage value of the original management subnet fromdata, toboth. Here is an example showing the commands required and the output results:Enter the following command to activate the new configuration:# net activate config new_configAccess to the management interface using the originally configured IP addresses should now be successful.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.