Document VersionRelease DateDetails210 July 2018Changed the title, changed the first sentence of the Description, replaced the Scope section, and changed the first sentence of the Resolution117 January 2018Original Document ReleaseSolid State Drive (SSD) models starting with "AREX" installed in an HPE 3PAR StoreServ Storage system may log a false critical temperature alert. This is cleared within one or two minutes, as shown by the example alerts below, and the drive continues to operate normally:The temperature listed for the SSD during this brief period is incorrectly reported at "135C", which can be displayed using the CLI commandshowpd -e:
This issue applies to the following Solid State Drive (SSD) models installed in an HPE 3PAR StoreServ Storage system:AREX0400S5xnNTRIAREX0480S5xnNTRIAREX0920S5xnFTRIAREX0920S5xnNTRIAREX1920S5xnNTRIAREX1920S5xnFTRIAREX3840S5xnFTRIAREX3840S5xnNTRI
The critical temperature alert described in the Description section of this advisory can be safely ignored if it is for an AREX SSD model installed in an HPE 3PAR StoreServ Storage system, and the alert is cleared within one or two minutes. The temperature of the SSD can be monitored with the CLI commandshowpd -e.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.