Loading...
Loading...
HPE StoreServ with Inform OS 3.3.1 Guided Setup with certain drive types require special installation. During an HPE 3PAR StoreServ 9450 or 208xx installation with HPE 3PAR OS 3.3.1.215 (GA/EGA) installed, the HPE 3PAR Service Processor (SP) guided setup of the HPE 3PAR StoreServ Storage system can fail with anadmitpdtimeout if the drive model is not defined in the HPE 3PAR OS firmware database. This issue causes the drives to reflect an unknown status.Below is a list of drives that are not included in the 3.3.1.215 firmware database:Drive ModelSystem supported onAREA0400S5xnNTRI9000/20000DDYE0400S5xnNMRI9000/20000AREA1920S5xnNTRI9000/20000DDYE1920S5xnNMRI9000/20000AREA3840S5xnNTRI9000/20000DDYE3840S5xnNMRI9000/20000DDYM7680S5xnNMRI9000
This issue affects HPE 3PAR StoreServ 9450 and 208xx systems.
This issue will be addressed in a future HPE 3PAR OS release. Until this release is available, if you have any of these drives in the array, contact your HPE Service Provider for installation of the product.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from