Document VersionRelease DateDetails26 April 2018Updated the Resolution with the version containing the fix117 July 2017Original Document ReleaseWhen Smart SAN is enabled, users can see a list of the hosts in theCreate HostorEdit Hostdialog that are visible to the array. When one of these hosts is selected, several attributes (such as the path details) are automatically set based on the information provided by Smart SAN. If the path information is not modified before creating the host, the resulting target zones will not be defined correctly; the zones will be created with all of the host's WWNs, rather than just the host WWNs that exist on each fabric. Alternatively, the zones for each of the array's ports may not include all of the host WWNs. If one or more paths between the host and array fail, this could lead to an unexpected loss of access to the array. Editing the host in HPE 3PAR StoreServ Management Console (SSMC) 3.1 can result in the same issues mentioned above.
This issue occurs when trying to use HPE 3PAR SSMC 3.1 to create or edit Fibre Channel hosts using Smart SAN.
This issue is fixed in HPE 3PAR StoreServ Management Console (SSMC) version 3.2.NOTE: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.