Document VersionRelease DateDetails201/03/2018Updated Resolution with permanent fix, iLO Chassis Manager 1.54105/25/2017Original document releaseGalois/Counter Mode (GCM)-based ciphers in the HPE Integrated Lights-Out (iLO) Chassis Manager (CM)supported client cipher list may fail to connect.For example:TLS_RSA_WITH_AES_256_GCM_SHA384TLS_RSA_WITH_AES_128_GCM_SHA256TLS_DHE_RSA_WITH_AES_256_GCM_SHA384TLS_DHE_RSA_WITH_AES_128_GCM_SHA256If the application cipher list is reduced to only GCM ciphers, it will not be possible to connect to iLO CM. This is more likely to be seen when using directory authentication.
Any HPE Moonshot 1500 Chassis running iLO Chassis Manager with a firmware version less than version 1.54.
Chassis Manager 1.54 (and later), which is delivered with the Moonshot Component Pack 2017.06.0, will correct this issue:The latest versions of the Moonshot Component Packs are available here:http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=5409784As a workaround, do not restrict the accepted ciphers list in the client; do not configure the client to only accept these ciphers.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.