Document VersionRelease DateDetails201/18/2018Revised the Resolution section.105/12/2017Original Document Release.Hewlett Packard Enterprise Recovery Manager Central (RMC) appliances do not boot when the VMDirectPath I/O (PCI pass-through) is configured for 16Gb QLogic FC HBAs on HPE ProLiant servers with legacy BIOS mode enabled. This issue occurs when port 0 of the HBA is connected to the HPE RMC appliance as a PCI device.Legacy BIOS is enabled by default in all HPE ProLiant Gen8 servers. With later-generation servers, UEFI BIOS mode is enabled by default.
This issue affects HPE Recovery Manager Central Software 1.0.0 and later versions on HPE ProLiant servers with the legacy BIOS mode enabled.
To resolve this issue, use one of the following options:Use UEFI BIOS mode on the HPE ProLiant server, if applicable.orConnect an FC HBA port, other than port 0, as the PCI pass-through device to the HPE RMC appliance on the server with legacy BIOS mode.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form