An issue has been identified on HPE StoreOnce Backup Systems where, after upgrading to software version 3.15.1 or later, the Catalyst Over Fibre Channel (CoFC) WWNN and WWPN values may change and access to fibre channel devices is lost.This issue will only occur if the default values for any of the following HPE StoreOnce Catalyst Fibre Channel settings are changed, prior to upgrading from software version 3.13.x to version 3.15.1 or later:Port SpeedTopologyNumber of devices per ApplianceHere is an example of the issue where the HPE StoreOnce GUI shows that the Port Speed has been changed from default to 4Gb/s. This will cause the CoFC WWNN and WWPN values to change after upgrading to software version 3.15.1 or later, and the FC devices will not be accessible:Here is an example of an HPE StoreOnce GUI showing the default values for Port Speed, Topology, and Number of devices per appliance. This system will not be affected by this issue:
This issue affects the following HPE StoreOnce systems being upgraded from software version 3.13.x to version 3.15.1 or later:BB896A HPE StoreOnce 6500 BackupBB897A HPE StoreOnce 6500 120TB CoupletBB910A HPE StoreOnce 2900 BackupBB903A HPE StoreOnce 4900 BackupBB877A HPE StoreOnce 2700 8TB BackupBB878A HPE StoreOnce 4500 24TB BackupBB879A HPE StoreOnce 4700 24TB Backup
This issue is resolved in HPE StoreOnce software version 3.16.2 available on 27 March 2017 for systems usingN_PortFC topology, and will be resolved in the next software version 3.16.x release for systems configured inloopmode.WorkaroundUntil this issue is resolved, re-zoning the Fibre Channel network will correct this issue.Alternately, contact HPE Support for assistance with restoring the original WWNN and WWPN values.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.