Document VersionRelease DateDetails208/07/2018Removed the Resolution and made the Workaround the Resolution.104/04/2018Original Document Release.If you change the host name (the computer name in Windows) of the XP7 Configuration Manager REST API server, including the virtual appliance, the reception of sending notifications about changes to storage system configurations may fail. As a result, you might not register a storage system, and the resource information of the registered storage systems used for the search function might not be kept up to date.NOTE: In the REST API server that XP7 Configuration Manager is installed, except virtual appliance, do not change the host name (the computer name in windows) of the server.Storage System Errors:When you register a storage system for which the value for the "isNotifiable" parameter is "true," the KART40166-E error occurs.When you register a storage system without specifying a value for the "isNotifiable" parameter, the REST API server is not displayed in the result of getting a list of destinations for sending notifications about changes to storage system configurations.When storage systems are already registered, the resource information of the storage systems used for the search function might not be kept up to date because the REST API database used for the search function cannot be automatically updated.
Device Manager 5.0-00 and later is affected by this issue.
To avoid this issue, do not change the name of the REST API server. If you do change the name of the REST API server, follow the workaround below for Windows or Linux.NOTE: No resolution exists for the virtual appliance if the server name is changed.Windows:Edit the <XP7 Configuration-Manager-installation-destination>\oss\rabbitmq\etc\rabbitmq\rabbitmq-env-conf.bat file, and delete the following line: Set RABBITMQ_NODENAME=rabbitRun <XP7 Configuration-Manager-installation-destination>\sbin\install.bat.Run < XP7 Configuration-Manager-installation-destination>\start.bat.Linux:Run < XP7 Configuration-Manager-installation-destination>/sbin/install.bat.Run < XP7 Configuration-Manager-installation-destination>/start.bat.Windows and Linux:When storage systems are already registered, register destinations for sending notifications about changes to the storage system configurations again.See theREST API Reference Guide. Delete destinations for sending notifications about changes to storage system configurations, and register the destinations.NOTE: No solution exists for the XP7 Configuration Manager provided in the virtual appliance.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.