Loading...
Loading...
Known affected versions were inferred from fixed-version data and were not explicitly confirmed by the vendor: 7.6.6
You may be able to reduce FGCP HA failover times by changing the the NP7 link scan interval. The NP7 link scan interval is the amount of time that a FortiGate with NP7 processors waits between scans to determine if a link has failed. A shorter NP7 link scan interval can cause the FortiGate to send gratuitous ARP packets sooner after an HA failover has occurred. config system npu set np-linkscan-interval endThe np-link-scan-interval range is 50 to 1000ms. The default NP7 link scan interval is 1000 milliseconds (ms). If your FGCPHA cluster experiences longer than expected HA failover delays (for example a 2-second interval for a failover to occur)reducing the NP7 link scan interval may reduce HA failover delays.
Fortinet Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.