Following Signature Update (-SignatureFile_20200921_124008 or later), newly added/activated policies may fail Apply Policy due to a duplicate key database error: 01310027:2: subsystem error (asm_config_server.pl,F5::SetActive::Impl::set_active): Setting policy active failed: Failed to insert to DCC.ACCOUNT_NEGSIG_SIGNATURE_PROPERTIES (DBD::mysql::db do failed: Duplicate entry '8112518117000363265' for key 'PRIMARY' at /usr/local/share/perl5/F5/BatchInsert.pm line 219. )
Apply policy fails.
Signature Update -SignatureFile_20200921_124008 is installed, and a newly imported or inactive policy is applied.
You can use any of the following workarounds: -- Install an older signature update -SignatureFile_20200917_175034 -- Disable staging for either signature 200101255 or signature 200101258 (or both) in the affected policies. The policy can then be successfully applied. -- Run the following SQL command to correct all affected policies on the device: ---------------------------------------------------------------------- UPDATE PL_POLICY_NEGSIG_SIGNATURES policy_sigs INNER JOIN (select previous_enforced_rule_md5, policy_id, count(*) as mycount from PL_POLICY_NEGSIG_SIGNATURES where previous_enforced_rule_md5 != '' group by previous_enforced_rule_md5, policy_id having mycount > 1) as multi_sigs on policy_sigs.policy_id = multi_sigs.policy_id and policy_sigs.previous_enforced_rule_md5 = multi_sigs.previous_enforced_rule_md5 SET policy_sigs.previous_enforced_rule_md5 = '', policy_sigs.previous_enforced_rule = ''; ----------------------------------------------------------------------
None
Click on a version to see all relevant bugs
F5 Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.