Loading...
Loading...
Mcpd errors are found in /var/log/ltm: -- err mcpd[16068]: 01070734:3: Configuration error: MCPProcessor::initializeDB: basic_string::_S_create -- err mcpd[16068]: 01070596:3: An unexpected failure has occurred, basic_string::_S_create, exiting... -- err mcpd[16978]: 01b50049:3: FipsUserMgr Error: Master key load failure.
MCPD does not restore the configuration from its binary database, but instead re-reads the text config files (bigip.conf, et al.).
-- Restart MCPD (e.g. by rebooting the BIG-IP) -- This affects BIG-IP v15.1.0.4 running on all platforms with the exception of the following: + i5820-DF / i7820-DF + 5250v-F / 7200v-F + 10200v-F + 10350v-F
None.
MCPD is again able to restore its configuration from the binary database during startup
F5 Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.