As a part of FPGA firmware update, "tmsh load sys config" fails. Chmand reports errors: chmand[19052]: FPGA firmware mismatch - auto update, No Interruption! chmand[19052]: 012a0006:6: FPGA HSB firmware uploading now...use caution! Reloading fw_update_post configuration (via systemctl): [FAILED]
Firmware update fails.
Running either of the following commands: tmsh load sys config /etc/init.d/fw_update_post reload
Use this procedure: 1. Mount /usr: mount -o rw,remount /usr 2. Add the following line to the '/usr/lib/systemd/system/fw_update_post.service' file: ExecReload=/etc/init.d/fw_update_post reload 3. Reload systemctl: systemctl daemon-reload 4. Reload the file: /etc/init.d/fw_update_post reload
Added the reload option in fw_update_post service file.