GTM logs an error message for GTM BIG-IP virtual server without BIG-IP monitor: err gtmd[9402]: 011ae10d:3: Could not find a monitor instance of type /Common/bigip monitoring 10.10.10.10:443 on server:vs /Common/my_vs
Confusing error log message.
Multiple virtual servers configured with the same IP/Port and GTM receives a BIG-IP monitor response for this IP/port. This issue can also occur when a 'depends-on' configuration is applied to a second virtual server which has a non-BIG-IP monitor configured on it. For example: gtm server test { addresses { 10.0.0.100 } datacenter dc1 monitor BIG-IP virtual-servers { vs1 { destination 10.0.0.1:80 } vs1_other { depends-on { test:vs1 } destination 10.0.0.1:80 monitor gateway_icmp } } }
- Add a BIG-IP monitor to the virtual servers. - Suppress the messages using a log filter with no publisher. tmsh create sys log-config filter drop_011ae10d message-id 011ae10d source gtmd