For Thales: The ltm/log shows SSL handshake failures with similar lines (this is for Diffie-Hellman Key Exchange): -- warning bigip1 tmm1[28813] 01260013 SSL Handshake failed for TCP 192.0.2.1:5106 -> 192.0.2.200:5607 -- warning bigip1 tmm1[28813] 01260009 Connection error: ssl_hs_vfy_sign_srvkeyxchg:13583: sign_srvkeyxchg (80) -- debug bigip1 tmm1[28813] 01260036 FIPS acceleration device error: fips_poll_completed_reqs: req: 4 status: 0x1 : Cancel -- err bigip1 pkcs11d[26259] 01680002 Key table lookup failed. error. After enabling pkcs11d debug, the pkcs11d.debug log shows: -- 2019-10-03 11:21:50 [6399] t00075a9a462b0000: pkcs11: 000008D9 D obj_match_attribute class CKO_PRIVATE_KEY attribute CKA_CLASS -- 2019-10-03 11:21:50 [6399] t00075a9a462b0000: pkcs11: 000008D9 D obj_match_attribute type CKA_CLASS matches -- 2019-10-03 11:21:50 [6399] t00075a9a462b0000: pkcs11: 000008D9 D obj_match_attribute class CKO_PRIVATE_KEY attribute CKA_ID -- 2019-10-03 11:21:50 [6399] t00075a9a462b0000: pkcs11: 000008D9 D obj_match_attribute type CKA_ID does not match <=== For Safenet: -- warning tmm1[17495]: 01260009:4: Connection error: ssl_hs_vfy_sign_srvkeyxchg:13544: sign_srvkeyxchg (80) -- warning tmm1[17495]: 01260013:4: SSL Handshake failed for TCP 10.1.1.11:6009 -> 10.1.1.201:443 -- err pkcs11d[5856]: 01680002:3: Key table lookup failed. error.
SSL handshake failures.
1. Keys were created on earlier versions of BIG-IP software, no matter if using tmsh (Safenet) or using fipskey.nethsm (Thales, Safenet) and the device was upgraded to 14.1.0 or later. 2. Keys were created on BIG-IP v14.1.0 or later directly, using fipskey.nethsm (Thales). For Safenet, fipskey.nethsm was deprecated in 14.0.0.
There are two workarounds: -- Re-create the keys using tmsh command. IMPORTANT: This workaround is suitable for deployments that are new and not in production. -- Re-import the keys from nethsm using: tmsh install sys crypto key <key_label> from-nethsm You can find the key_label here: -- The rightmost string in the output of the Thales command: nfkminfo -l -- The string after label= in the 'cmu list' command for Safenet.
None
Click on a version to see all relevant bugs
F5 Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.