SFP interfaces are reported as missing: # tmsh show net interface 2.0 -------------------------------------------------------- Net::Interface Name Status Bits Bits Pkts Pkts Drops Errs Media In Out In Out -------------------------------------------------------- 2.0 miss 0 0 0 0 0 0 none sys ha-status will report tmm ready-for-world as failed: # tmsh show sys ha-status ------------------------------------------------------------------------- Sys::HA Status Feature Key Action Fail ------------------------------------------------------------------------- ready-for-world tmm none yes ready-for-world tmm1 none yes ready-for-world tmm2 none yes ready-for-world tmm3 none yes ready-for-world tmm4 none yes ready-for-world tmm5 none yes
The BIG-IP system does not become ready after a reboot.
This has been seen on the i15800 and i11000 series BIG-IP platforms immediately after the system boots.
Mitigation if the system is in this state, restart tmm: # tmsh restart sys service tmm
An issue where the BIG-IP system failed to detect SFPs has been resolved.