Loading...
Loading...
Using the platform-migrate option to load a UCS from a different platform may show this error from loaddb: 01080023:3: Error return while getting reply from mcpd: 0x107178a, 0107178a:3: Modifying license.maxcores to a value other than 8 is not allowed. The UCS loads successfully, other than the DB variable, but this error message is printed and the DB variables are not loaded.
The DB variable file fails to load, generating the error message, but that does not stop the loading of the regular configuration files in BIG-IP*.conf.
-- Migrating a UCS from physical platform hardware to a Virtual Edition (VE) configuration. -- License has an attribute limiting the maximum number of cores, and the incoming UCS has a value of the DB variable 'license.maxcores' that contradicts this.
The 'license.maxcores' value is ignored on hardware devices, so set it to 8 before saving the UCS.
None
Click on a version to see all relevant bugs
F5 Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.