EPSEC installation fails with no specific reason provided in the error message.
Difficult to debug actual EPSEC installation failure reason.
This happens only when there is a version mismatch between the EPSEC RPM's database and the shared RPM database on the BIG-IP system. Often this happens if a switchboot is issued to activate an earlier version of BIG-IP software from a later version. The RPM database is shared, so on a switchboot, the RPM database version is not downgraded. This causes the subsequent EPSEC installation to fail. Although this is expected behavior, the reason for failure is not logged.
None.
The system now logs the EPSEC installation failure reason.