When a BIG-IP management interface is accessed through a Reverse Proxy, you are not able to log in to the Configuration Utility. Instead you will see a login error, as the Reverse Proxy IP/hostname is in the Referer header instead of that of the BIG-IP.
You are unable to login to the Configuration Utility.
You are accessing the BIG-IP Configuration Utility through a Reverse Proxy.
Configure their Reverse Proxy to place the IP address of the BIG-IP in the Referer header.
None
Customers who are utilizing the BIG-IP Configuration Utility behind a reverse proxy that does not transparently set the Referer header will be unable log in. Prior to the change, there were no restrictions on logging in.