Outdated and unused unit key is left on some devices after an upgrade from an older version. - This occurs with 5000- and 7000-series platforms after upgrade from an older version to v13.0.0. - This occurs with iSeries platforms after upgrade from an older version to v12.1.4.1 or a later v12.1.x software version.
1) Unit key on disk is preferred over unit key in hardware. 2a) Potential config load failures when installing v13.0.0 hotfixes on 5000- and 7000- series devices. 2b) Potential config load failures when installing v12.1.x point releases or hotfixes on iSeries devices.
One of the following sets of conditions: -- Running on 5000- and 7000-series platforms. -- Upgrading from a version earlier than v13.0.0 to v13.0.0. -- Installing v13.0.0 hotfixes Or: -- Running on iSeries platforms. -- Upgrading from v12.1.4 or earlier, to 12.1.4.1 or a later 12.1.x version. -- Installing v12.1.x point releases or engineering hotfixes.
NOTES: -- Impacts 5000- and 7000-series platforms on v13.0.x. -- Impacts iSeries platforms on v12.1.4.1 or a later v12.1.x software version. On or before upgrade to v13.0.0 or its associated hotfixes, perform the following procedure: 1) Set master key to a known value: modify sys crypto master-key prompt-for-password 2) Save config: tmsh save sys config 3) Remove the old unit key: rm /config/bigip/kstore/.unitkey 4) Load config: tmsh load sys config 5) Save config: tmsh save sys config
Unit key is no longer left on platforms after upgrade from an older version.