After the SafeNet Hardware Security Module (HSM) is restarted, users cannot generate a new key.
HSM service is not usable even after restarting pkcs11d. Users must re-authenticate.
The BIG-IP system uses the SafeNet HSM.
To generate a new key, after HSM finishes starting up, run the following commands: # /shared/safenet/toolkit/sautil -v -s 1 -i 10:11 -c # /shared/safenet/toolkit/sautil -v -s 1 -i 10:11 -o -p <hsm_partition_password> Or, you can reinstall SafeNet client.
After the SafeNet Hardware Security Module (HSM) is restarted, users can now generate a new key.