Loading...
Loading...
Upgrading from 11.3 or 11.4 fails if the config has a DOS application profile with a "Prevention Duration" value higher than 3600 or lower than 4.
Upgrade fails. 010715d5:3: The escalation period in TPS-based anomaly is out of range [1..3600]. Unexpected Error: Loading configuration process failed.
Upgrading to 11.5.0 through 11.6.1 from 11.3.x or 11.4.x Configuration before the upgrade had a DOS profile with application enabled and "Prevention Duration" value set to a value higher than 3600 or lower than 4.
Set the max-prevention-duration value to the default value of "unlimited" before the upgrade, or within the UCS before installing it (by editing the bigip.conf file within the UCS tarball).
Upgrading from 11.3/11.4 no longer fails when the config had a DOS application profile with "Prevention Duration" value set to a value higher than 3600 or lower than 4.
Click on a version to see all relevant bugs