Cannot use tmsh to load a valid configuration created using the GUI.
Although the configuration is valid, it fails to load with error: err iqsyncer[16456]: 011ae104:3: Gtm config sync result from local mcpd: result { result_code 17237538 result_message '01070622:3: The monitor /Common/my-tcp-half has a wildcard destination service and cannot be associated with a node that has a zero service.' }
This occurs with the following configuration: 1) Configure server with :* members. 2) Configure member-specific gateway-icmp monitor for the :* member. 3) Assign any L4/7 monitor at the server level. (http/tcp, etc., with the default '*:*' destination in the monitor).
Remove the parent TCP monitor.
The server configuration of :* members now loads without error using tmsh.