A BIG-IP system may not clear a crypto-failsafe condition after recovering from a cryptographic hardware lockup. As a result of this issue, you may encounter one or more of the following symptoms: The output of the tmsh show sys ha-status command appears similar to the following example: ------------------------------------------------------------------------------- Sys::HA Status Slot Feature Key Action Fail ------------------------------------------------------------------------------- 1 crypto-failsafe cn-crypto-11 failover yes In the /var/log/ltm file, you observe messages similar to the following examples: -- crit tmm[9184]: 01010025:2: Device error: crypto codec cn-crypto-0 queue is stuck. -- notice sod[8874]: 01140029:5: HA crypto_failsafe_t cn-crypto-0 fails action is failover.
If the crypto-failsafe action is to fail over, you will be unable to activate the BIG-IP system even after the cryptographic hardware recovers.
This issue occurs when all of the following conditions are met: -- Your BIG-IP platform uses internal cryptographic hardware (such as, for vCMP, a Nitrox Lite SSL hardware accelerator card) or external cryptographic hardware (such as SafeNet/Thales hardware security module (HSM)). -- The cryptographic hardware fails and subsequently recovers.
To restore the crypto-failsafe high availability (HA) fail status, restart tmm by issuing the following command: bigstart restart tmm. Note: On VIPRION platforms, this command must be run on the appropriate blade.
The system now allows the crypto device to be restored and not keep the crypto-failsafe HA status in the fail state.
Click on a version to see all relevant bugs
F5 Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.