GTM external monitor is not correctly synced in GTM sync group without device group.
The GTM external monitor is not synced correctly and configuration fails on the peer GTM system. The system posts an error similar to the following: err iqsyncer[20361]: 011ae104:3: Gtm config sync result from local mcpd: result { result_code 17237778 result_message '01070712:3: Values (/Common/bad_external_monitor.sh) specified for external monitor parameter (/Common/external_test 2 RUN_I=): foreign key index (to_file) do not point at an item that exists in the database.' }
This occurs when the following conditions are met: 1. GTM systems exist in the same GTM sync group but not in the same device group. The GTM external monitor refers to non-default system file.
Configure both GTM systems in the same GTM sync group and the same device group.