LSN Translation failures in persistence mode when cmp-hash is set to src-ip on ingress VLAN and to dst-ip on egress VLAN.
Translation failures. The system posts an error similar to the following: debug tmm9[25268]: 01670012:7: [0.9] Translation failed client 200.200.200.101,10096.
Persistence is enabled on the LSN pool, and cmp-hash is set to src-ip on ingress VLAN and to dst-ip on egress VLAN, when the lsn-pool port range is relatively small (under 1000), or a blade is added or removed. Translation mode is NAPT or PBA.
Adequately provision the LSN pool.
This release resolves CGNAT translation failures in persistence mode when cmp-hash is set to src-ip on ingress VLAN and to dst-ip on egress VLAN.