The big3d agent restarts periodically if a v11.4.0 or earlier system with Common Criteria mode enabled is updated with a newer version of the big3d agent.
The impact of this issue is periodic restarting of the big3d agent.
A v11.4.0 or earlier system is updated to run a newer version of the big3d agent and Common Criteria mode is enabled.
Disable Common Criteria mode. Alternatively, restore the prior version of the big3d agent.
The big3d agent has been modified to run in a mode that eliminates inconsistencies with version 11.4.0 and earlier.