When a power supply or fan tray FRU is inserted into a running BIG-IP system, a critical alarm may be raised indicating low power and/or fan speeds. This is due to the amount of time it takes for the power and/or fan speed levels to reach their steady state levels relative to when the sensors are monitoring them.
Critical alarm raised for temporary, non-serious issue.
Insertion of power supply or fan tray FRU.
None. This is a cosmetic issue. Whenever you insert a power supply or fan tray, there is a certain amount of time required for the power or fan speeds to stabilize within their normal ranges. The firmware may report a low voltage or fan speed from the initial readings.
None