If you specify a timeout greater than 65535 on a GTM monitor, it does not set the value as expected. Before saving the configuration, tmsh reports the value that was entered, but the wideip.conf file contains a value of 0. After the configuration is saved, the value returns to the default of 120 in both tmsh and wideip.conf.
If the timeout is set to greater than 65535 it does not work as expected. Instead the monitor timeout defaults to 120 seconds.
Creating/Modifying a GTM monitor with a timeout greater than 65535.
Specify a timeout less than 65536.
Setting the timeout now works as expected.