After upgrading to an affected version, a configuration containing both a wildcard IP-forwarding virtual server and a second virtual server using a Traffic Matching Criteria (TMC) with a source address list may fail to load with the following error: 0107176c:3: Invalid Virtual Address, the IP address 0.0.0.0 already exists. Unexpected Error: Validating configuration process failed.
The BIG-IP system fails to load its configuration after upgrade, interrupting traffic processing
All of the following must be true: - A wildcard IP-forwarding virtual server exists with destination 0.0.0.0:0 and mask any - A second virtual server in any partition references a TMC configured with: - destination-address-inline 0.0.0.0 (any destination) - destination-port-inline <port> - source-address-list <list-name> - No destination-address-list - The configuration is loaded from disk (upgrade, reinstall, or MCP force-reload)